background image

10

Parameter reference

10.3

Parameters of the communication module for slot MXI2

96

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14075

C14078

C14079

Parameter | Name:

C14075 | EPL SDO channel width

Data type: UNSIGNED_16

Index: 10500 = 0x2904

EPL index: 0x1F98.0x08

The code defines the maximum user data size of asynchronous frames. Protocol-specific headers for POWERLINK,

UDP/IP and others as well as service-specific headers are to be interpreted as part of the user data.

In the configured state, the C14075 values of all EPL nodes must be identical.
Setting range

(min. value | unit | max. value)

Lenze setting

282

Byte

1500 282 bytes

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14078 | EPL CN: Max. time - MN detection

Data type: UNSIGNED_32

Index: 10497 = 0x2901

EPL index: 0x1F99

The code defines the time interval needed for detecting a managing node. If a booting controlled node detects a

managing node during the interval, it changes to NMT_CS_PREOPERATIONAL_1. If not, it changes to "Basic Ethernet

Mode".
Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

4294967295 10000000 μs

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14079 | EPL multi-stage node declaration CN

Data type: UNSIGNED_8

Index: 10496 = 0x2900

EPL index: See subcodes

This code indicates in which multiplexed cycle the controlled node is queried. The value entered must not exceed

the value in code

C14074

.

If, for instance, the value "3" is entered in code

C14074

, the multiplexed cycle is repeated every three cycles. If now

the value "3" is entered for one node in C14079/x, it is always queried only in the second cycle of the three

multiplexed cycles.
Setting range

(min. value | unit | max. value)

0

Cycles

255

Subcodes

Lenze setting

Info

EPL index

C14079/1

0 cycles

0x1F9B.0x01

...

...

...

C14079/100

0 cycles

0x1F9B.0x64

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT