Parameter reference

10.2

Parameters of the communication module for slot MXI1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13095

C13102

C13110

Parameter | Name:

C13095 | EPL communication status

Data type: UNSIGNED_8

Index: 11480 = 0x2CD8

EPL index: 0x1F8C

The code indicates the current NMT status of the EPL node.
Selection list

(read only)

Info

0 Off

NMT_GS_OFF

25 Initialising

NMT_GS_INITIALISING

41 ResetAppl

NMT_GS_RESET_APPLICATION

57 ResetComm

NMT_GS_RESET_COMMUNICATION

121 ResetConfig

NMT_GS_RESET_CONFIGURATION

28 NotActive

NMT_CS_NOT_ACTIVE

NMT_MS_NOT_ACTIVE

29 PreOp1

NMT_CS_PRE_OPERATIONAL_1

NMT_MS_PRE_OPERATIONAL_1

93 PreOp2

NMT_CS_PRE_OPERATIONAL_2

NMT_MS_PRE_OPERATIONAL_2

109 ReadyToOp

NMT_CS_READY_TO_OPERATE

NMT_MS_READY_TO_OPERATE

253 Operational

NMT_CS_OPERATIONAL

NMT_MS_OPERATIONAL

77 Stopped

NMT_CS_STOPPED (only controlled node)

30 BasicEthernet

NMT_CS_BASIC_ETHERNET (only controlled node)

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13102 | EPL reset command

Data type: UNSIGNED_8

Index: 11473 = 0x2CD1

EPL index: 0x1F9E

A reset command to a single EPL node in the network can result in cycle and monitoring errors.

The code initiates a reset of the EPL node.

When the reset has been executed, the code is automatically set to "NMTInvalidService".
Selection list

(Lenze setting printed in bold)

Info

40 ResetNode

Status transition  NMT_GS_RESET_APPLICATION

41 ResetCommunication

Status transition  NMT_GS_RESET_COMMUNICATION

42 ResetConfiguration

Status transition  NMT_GS_RESET_CONFIGURATION

255 No command

No function

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13110 | EPL fault memory

Data type: UNSIGNED_8

Index: 11465 = 0x2CC9

EPL index: 0x1001

The code indicates the currently pending errors (according to error classes).

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT