10

Parameter reference

10.2

Parameters of the communication module for slot MXI1

78

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13225

C13229

C13231

Parameter | Name:

C13225 | EPL MN: Max. user data RPDO

Data type: UNSIGNED_16

Index: 11350 = 0x2C56

EPL index: See subcodes

The code defines the reserved user data length of the PRes frames. Each subcode number corresponds to an EPL

node with the same node ID.

The subcode describes the PRes frames received. The value must be within the limits of 36 ... 1490 bytes.

The values are upper limit values for the total size of the PDO mappings which must be defined each one of the

codes

C13231

...

C13240

for PRes frames received.

In the configured state, the values stored for the EPL nodes must be identical to the corresponding

C13072

entries.

C13066

must have an identical value in all EPL nodes of the network.

Setting range

(min. value | unit | max. value)

0

Byte

1490

Subcodes

Lenze setting

Info

EPL index

C13225/1

0 byte

Managing node

0x1F8D.0xF0

C13225/2

0 byte

Diagnostics device

0x1F8D.0xFD

C13225/3

0 byte

router

0x1F8D.0xFE

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13229 | EPL multi-stage node declaration MN

Data type: UNSIGNED_8

Index: 11346 = 0x2C52

EPL index: See subcodes

This code indicates in which multiplexed cycle the node is queried. The value entered must not exceed the value in

code

C13074

.

If, for instance, the value "3" is entered in code

C13074

, the multiplexed cycle is repeated every three cycles. If now

the value "3" is entered for one node in C13229/x, it is always queried only in the second cycle of the three

multiplexed cycles.
Setting range

(min. value | unit | max. value)

0

Cycles

255

Subcodes

Lenze setting

Info

EPL index

C13229/1

0 cycles

Managing node

0x1F9B.0xF0

C13229/2

0 cycles

Diagnostics device

0x1F9B.0xFD

C13229/3

0 cycles

router

0x1F9B.0xFE

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13231 | EPL RPDO

Data type: UNSIGNED_64

Index: 11344 = 0x2C50

EPL index: See subcodes

EPL RPDO-1
Subcodes

Lenze setting

Info

EPL index

C13231/1

0

EPL RPDO

0x1600.0x01

...

...

...

...

C13231/32

0

EPL RPDO

0x1600.0x20

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT