Error messages of the communication module

60

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

EPL: MN address assigned double [0x00c88283]

EPL: Internal error [0x00c88284]

Response (Lenze setting printed in bold)

Setting: not possible

No reaction  System fault  Fault  Trouble  Quick stop by trouble  WarningLocked  Warning  Information

Cause

Remedy

The address setting of the Managing Node has been

assigned several times (node ID = ’240’).

This node is configured as Managing Node but does not

participate in the frame traffic due to double addressing.

Correct address setting.

Node address setting ( 35)

Response (Lenze setting printed in bold)

Setting: not possible

No reaction  System fault  Fault  Trouble  Quick stop by trouble  WarningLocked  Warning  Information

Cause

Remedy

Internal error.

Send communication module together with a

description of the fault to Lenze.