2 communication time, Communication time, 4technical data – Lenze E94AYCEC User Manual

Page 17

Advertising
background image

Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17

17

4

Technical data

4.2

POWERLINK communication data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.2

Communication time

Parameter data (SDO)
The communication time for parameter data is the time between the transmission of an SDO

request and the arrival of the corresponding response.

• The processing time in the Servo Drive 9400 is approx. 30 ms + 20 ms tolerance (typical)
• For some codes, the processing time may be longer (see reference manual/»Engineer« online

help for the Servo Drive 9400).

Process data (PDO)
The communication time for process data is the time between the reception of a PDO with setpoints

and the return of a PDO with the current actual values.
The communication times for process data depend on ...

• processing time in the Servo Drive 9400 (interval time of the application task, process data

mode);

• Telegram runtime on the fieldbus (telegram length, number of nodes, PDO update time, instant

of transmission of the POWERLINK telegram);

• Use of the synchronisation to the POWERLINK cycles.

Processing time
The basic conditions mentioned above cause the following processing times for the process data in

the Servo Drive 9400:

• Process data for synchronised operation: approx. 1.2 ms
• Process data for non-synchronised operation: approx. 3.0 ms