Response code – Rockwell Automation 900 Temperature Controller Communications Functions - Series B User Manual

Page 25

Advertising
background image

Publication 900-UM004D-EN-E - July 2010

Bulletin 900 Communications Procedures 900-TCx (CompoWay/F)

2-9

Response code

Normal Completion

Error Occurred

Table 2.8

Response
Code

Name

Description

0000

Normal completion

No errors were found.

Table 2.9

Response
Code

Error Name

Cause

1001

Command too long

The command is too long.

1002

Command too short

The command is too short.

1101

Area type error

The variable type is wrong.

1103

Start address out-of-range error The read start address is out of range.

110B

Response too long

The number of elements exceeds the
maximum/

1100

Parameter error

The bit position not 00.

2203

Operation error

EEPROM error

ATTENTION

!

Alarm function:
Even though alarms are not displayed on the controller's
display, they function normally in communications.