The table below shows the status details, Table 3.4 status details – Rockwell Automation 900 Temperature Controller Communications Functions - Series B User Manual

Page 57

Advertising
background image

Publication 900-UM004D-EN-E - July 2010

Communications Data

3-15

The table below shows the status details.

Table 3.4 Status Details

Bit
Position

Status

Bit Description

0

1

Status
(lower word)

0

Heater overcurrent (CT1)

Not generated

Generated

1

Heater current hold (CT1)➊

Updated

Hold

2

A/D Converter Error

Not generated

Generated

3

HS alarm (CT1)

OFF

ON

4

Spare

OFF

---

5

Display range exceeded

Not generated

Generated

6

Input error

Not generated

Generated

7

Spare

OFF

---

8

Control output (heating)

OFF

ON

9

Control output (cooling)

OFF

ON

10

HB (heater burnout) alarm output (CT1)

OFF

ON

11

HB (heater burnout) alarm output (CT2)

OFF

ON

12

Alarm 1

OFF

ON

13

Alarm 2

OFF

ON

14

Alarm 3 ➌

OFF

ON

15

Program end output

OFF

ON

Status
(upper word)

16

Event input 1

OFF

ON

17

Event input 2

OFF

ON

18

Event input 3 ➋

OFF

ON

19

Event input 4 ➋

OFF

ON

20

Write mode

Backup mode

RAM write mode

21

EEPROM

RAM = EEPROM

RAM

EEPROM

22

Setup area

Setup area 0

Setup area 1

23

AT execute/cancel

AT canceled

AT execution in progress

24

Run/Stop

Run

Stop

25

Communications writing

OFF (disabled)

ON (enabled)

26

Auto/manual switch

Automatic mode

Manual mode

27

Program Start

Reset

Start

28

Heater overcurrent (CT2)

Not generated

Generated

29

Heater current hold (CT2) ➊

Update

Hold

30

Spare

OFF

---

31

HS alarm output (CT2)

OFF

ON

➊ When the control output ON time is less than 100 ms, the bit is set to “1” and the heater current is held at the last current value.
➋ NA 900-TC8, 900YC16, 900-TC32
➌ Applies to 900-TC8
Note 1: Spare bits are always OFF.
Note 2: When read in setup area 1, the status of the bits will be as follows:

•Overcurrent: Last value held
•A/D converter error: Last value held
•Input error: Last value held
•HB and HS outputs: cleared
•Program end output: cleared
•Current hold: Last value held
•Display Range Exceeded: Last value held
•Heating and Cooling Outputs: cleared
•Alarm Outputs: cleared