Monitor Remote I/O Chapter 5

Global Diagnostic Counters

The global diagnostic counters provide information about the operation of the
entire Remote I/O network.

The following table lists the global diagnostic counters’ descriptions.

Scanner Mode Global Diagnostic Counters

Counter

Description

Tx

This counter increments each time the 1756-RIO module transmits a packet.

RxGood

This counter increments when the 1756-RIO module receives a good packet.

RxTout

This counter increments when the 1756-RIO module sends a packet but does not receive a reply.

RxBadCRC

This counter increments when the 1756-RIO module receives a packet with a bad Cyclic Redundancy Check (CRC). Check
cabling and termination on the Remote I/O network.

RxNoise

This counter increments when the 1756-RIO module hears a carrier without receiving a packet. Check cabling and
termination on the Remote I/O network.

RxAbort

This counter increments when the 1756-RIO module receives an opening flag, then the packet ends without a closing
flag.

PrtclErr

This counter increments when the 1756-RIO module receives a packet that makes no sense in terms of the protocol.

UpdAvg

Average update time for all configured racks. This is the average of the previous 64 updates.

UpdMin

Minimum update time for all configured racks.

UpdMax

Maximum update time for all configured racks.