Configure Adapter Mode Chapter 3
Clear Discrete Rack Data Mappings
Follow these steps to clear mappings for discrete(rack) data.
1. On the 56RioCfgAdpt dialog box, right-click on the rack and choose
Rack Map Discretes - Clear.
2. On the Clear Rack Map dialog box, confirm that you want to clear the
existing mappings and click Yes.
IMPORTANT
All of the preceding mapping and configuration examples
currently reside only within the 56RioCfgAdpt software and
must be downloaded to the 1756-RIO module.
See Set Communication Path and Download to the Controller in
the RSLogix 5000 Project on page 30
for download steps.