Chapter 8

Debugging Your DDMC32 System

8-9

Input History for a Transfer Line Station (SDS Instruction)

Input History for STATION 7R

accumulated time duration input state address

00:00:00.53 00:00:00.53 2 1 I:006/01

00:00:01.81 00:00:01.28 2 0 I:006/01

00:00:02.04 00:00:00.23 3 1 I:006/02

00:00:03.03 00:00:00.99 3 0 I:006/02

00:00:03.05 00:00:00.02 9 1 I:001/04

00:00:03.75 00:00:00.70 9 0 I:001/04

00:00:03.99 00:00:00.24 1 1 I:006/00

00:00:07.03 00:00:03.04 1 0 I:006/00

Press a key for desired histogram function.

RUN Hist:Started Mode:Paged Disk Recording Off Current Step:13

Start Stop Contin Paged Input Write

History History Mode Mode Trigger To Disk

F1 F2 F3 F4 F5 F8

You can perform the following tasks from the Input History screen:

If you want to:

Press this key:

Begin monitoring the current instruction.

[F1] - Start History

Stop monitoring the current instruction.

[F2] - Stop History

Display data continuously on the screen as new
data is collected. If new data is generated faster
that the display can be updated, eventually the data
buffers overflow and “Data Overrun” is displayed.

[F3] - Contin Mode

Display data one page at a time. Press Next Page
or Previous Page to scroll through the data.

[F4] - Paged Mode

Specify a starting point at which to activate the timer
and display. When the SDS instruction is looking at
a specified input, the timer is waiting for a transition.
When this occurs, the timer is set to zero and the
display screen is activated, logging all inputs from
that point on.

[F5] - Input Trigger

Store the input history on disk.

[F8] - Write to Disk