Configuring SDS Instructions

Chapter 4

4-20

Editing Instruction and Address Comments

To activate the cursor in the instruction comment window:

1.

From the SDS instruction screen:

Press

[F2] - Instr Comment

to edit instruction comments. The

system displays the Instruction Comment Editor screen, below.

Press

[F3] - Address Comment

to edit address comments. The

system displays the Address Comment Editor screen, next page.

Instruction Comment Editor Screen (PLC-5)

Smart Directed Sequencer I/O Input Defines Output Defines

Definition for Control Block 0: I:001/16 0: O:000/04

N10:0 1: I:001/15 1: O:000/01

2: I:001/14 2: O:000/02

3: B3/2 3:

+=Ins Cmt==+ +=Adr Cmt==+ 4: B3/3 4:

|DRILL | |FULL | 5: 5:

|MACHINE | |DEPTH LS | 6: 6:

|HEAD 1 | | | 7: 7:

| | | |

| | | |

+==========+ +==========+

Operator Interface Station Addr : 77

Timebase for Step Timer : 0.01

Enter instruction comment for : SDS,N10:0

Program Edit mode:Insert Col:1 Line:1 PLC–5/25 Addr 1

Delete Undel Delete Undel Delete Undel Accept/

Comment Comment Line Line Word Word Exit

F1 F2 F3 F4 F5 F6 F8