Chapter 5
Configuring DFA Instructions

5-16

The DFA instruction provides a feature which lets you enter the equivalent
of pre-stored text messages to relate to your inputs. When an input or
inputs change to the defined state (ON or OFF), the DDMC32 software
automatically generates the message on the operator interface terminal.

To enter your messages, follow the procedure below:

1.

Start on the Ladder Editing screen.

2.

Cursor to the DFA instruction and press

[F10] - Edit.

3.

Press

[F2] - I/O Edit.

The system displays the DFA Message screen:

DFA Message Screen

DFA for DFA 1 AT N9:0

No Input ID Input Message State

0 C4:01/ON TOOL CHANGE REQUIRED

1 I:000/02 LUBE FAULT

2 I:000/01 LUBE LEVEL LOW

3 I:000/06 NO PARTS PRESENT

4 I:B3/03 LOAD PARTS IN STA.5

5 I:000/04 PLACE MACHINE IN AUTO MODE

6 O:000/05 TIME TO CALL MAINTENANCE

7 T5:1/ON MACHINE OVER CYCLE

Press a function key or enter input number.

>

Rem Prog 5/25 Addr 5 DB_TEST

Change Display Exit Input Edit Input Accept

Mode Symbol Monitor Message State Edits

F1 F2 F3 F5 F7 F8 F10