Configuring SDS Instructions
Chapter 4
4-28
To configure or edit combinatorial equations, you must enter some additional
information not needed in transitional equations:
1.
Access the Edit Step screen, seen below. If you are editing, cursor to
EQx (x is equal to the number of the equation within the step); if you are
adding the equation, the equation field is blank. Press
[F1]-Equatn List.
The system displays the Equation List screen seen below:
Equation List Screen (PLC-5)
STEP 4 CLAMPING
Eq# |Equation
1 0 ON—>OFF
2 1 OFF–>ON
3 2 EQ1
4 3
Press a function key.
Rem RUN 5/25 Addr 1 DB_TEST
Equatn Cancel Toggle Edit
Zoom Equatn Equatn Equatn
F1 F5 F9 F10
From the Equation List screen, you can perform the following tasks:
If you want to:
Press this key:
View a large equation which will not fit in the
equation list..
[F1] - Equatn Zoom
Remove an equation from the equation list.
[F5] - Cancel Equatn
View the equation in an alternate form
(abbreviated or expanded).
[F9] - Toggle Equatn
Edit an existing or enter a new equation.