When you are finished, press – Rockwell Automation D64046.5.1 U MNL WIN DDMC User Manual

Page 57

Advertising
background image

Configuring SDS Instructions

Chapter 4

4-21

Address Comment Editor Screen (PLC-5)

Smart Directed Sequencer I/O Input Defines Output Defines

Definition for Control Block 0: I:001/16 0: O:000/04

N10:0 1: I:001/15 1: O:000/01

2: I:001/14 2: O:000/02

3: B3/2 3:

+=Ins Cmt==+ +=Adr Cmt==+ 4: B3/3 4:

|DRILL | |FULL | 5: 5:

|MACHINE | |DEPTH LS | 6: 6:

|HEAD 1 | | | 7: 7:

| | | |

| | | |

+==========+ +==========+

Operator Interface Station Addr : 77

Timebase for Step Timer : 0.01

Enter address comment for : I:001/14

Program Edit mode:Insert Col:1 Line:1 PLC–5/25 Addr 1

Delete Undel Delete Undel Delete Undel Accept/ Next Prev

Comment Comment Line Line Word Word Exit Address Address

F1 F2 F3 F4 F5 F6 F8 F9 F10

2.

Edit the instruction or address comment. The function keys for both
Editor screens are the same, except that the Address Comment Editor
screen has function keys for moving the cursor to the next or previous
address:

If you want to:

Press this key:

Delete the current comment.

[F1] - Delete Comment

Re-insert the last deleted comment where the cursor is.

[F2] - Undel Comment

Delete the line the cursor is on from the current
comment.

[F3] - Delete Line

Re-insert the last deleted line from a comment.

[F4] - Undel Line

Delete the word the cursor is on from the current
comment.

[F5] - Delete Word

Re-insert the last deleted word from a comment.

[F6] - Undel Word

Save the current comment and return to the I/O
Definition screen.

[F8] - Accept/Exit

For Address Comments Only:

Save the current comment and/or move the cursor to
the next address.

[F9] - Next Address

Save the current comment and/or move the cursor to
the previous address.

[F10] - Prev Address

3.

When you are finished, press

[F8] - Accept/Exit.

Advertising