Documenting the sds instruction, Press – Rockwell Automation D64046.5.1 U MNL WIN DDMC User Manual

Page 54

Advertising
background image

Configuring SDS Instructions

Chapter 4

4-18

7.

Press

[F10] - Accept Rung

.

Important: You must accept the rung to save the information you entered
into the SDS instruction.

The SDS instruction provides a documentation function that lets you describe
the instruction and its associated addresses. The documentation function also
lets you assign symbols to addresses.

To document your SDS, Press

[F5] - Documnt

from the I/O Definition screen.

The system displays the SDS Instruction Documentation screen.

SDS Instruction Documentation Screen (PLC-5)

Smart Directed Sequencer I/O Input Defines Output Defines

Definition for Control Block 0: I:001/16 0: O:000/04

N10:0 1: I:001/15 1: O:000/01

2: I:001/14 2: O:000/02

3: B3/2 3:

+=Ins Cmt==+ +=Adr Cmt==+ 4: B3/3 4:

|DRILL | |RETURNED L| 5: 5:

|MACHINE | |S | 6: 6:

|HEAD 1 | | | 7: 7:

| | | |

| | | |

+==========+ +==========+

Operator Interface Station Addr : 77

Timebase for Step Timer : 0.01

Press a function key.

Program Forces:None Data:Decimal Addr:Decimal PLC–5/25 Addr 1

Instr Address Modify Remove Display Save &

Comment Comment Symbol Symbol Symbol Contnue

F2 F3 F6 F7 F9 F10

Documenting the SDS
Instruction