Configuring SDS Instructions

Chapter 4

4-29

2.

Press

[F10] - Edit Equatn.

The system displays the Equation Editor screen, below. If you are editing
an existing equation, that equation appears in the lower left corner of your
screen. If you are configuring the equation for the first time, the lower
left corner is empty.

Equation Editor Screen (PLC-5)

STEP 4 CLAMPING

+========================+

Eq# |Equation | 1 I:000/01 |

1 0&4 | 2 I:000/02 |

2 | |

3 | |

| |

| |

| |

| |

| |

| |

| |

| |

+========================+

Press a function key.

0&4

Program 5/25 Addr 1 DB_TEST

Select Display & ! ON>OFF OFF>ON Accept

Input Symbol AND NOT Equatn

F1 F2 F4 F6 F8 F9 F10

3.

Cursor to an input in the selection window that you want to place in your
equation and press

[F1] - Select Input.

All available input operands appear in the selection window. As you
select an input, it disappears from this window.

The system displays the input you select in the lower left corner of the
screen.

4.

Select the operator you want to use in your equation:

If you want to:

Do this:

combine 2 or more inputs

1. Select an input and press

[F1]-Select Input

2. Press

[F4]-AND

.

3. Select the next input and press

[F1]-Select Input

(See the Important note on page 4-30.)

negate an input

1. Combine the inputs as shown above.
2. Place the cursor on the input you wish to negate and
press

[F6] - NOT.