Configuring SDS Instructions
Chapter 4
4-8
5.
Download the CAR file:
If you are using a PLC-5:
a.
Press
[F1] - Begin Restore.
The system prompts you to enter a file number.
b.
Type the file number and press
[ENTER].
The system returns to the Program Directory.
If you are using a PLC-5/250:
a.
Press
[F1] - Begin Oper.
The system prompts you to enter a program descriptor.
b.
Type the program descriptor, for example, 1CAR0, and press
[ENTER].
In the program descriptor, the first number refers to the number in
the thumbwheel window on the logic processor (in this case, 1). A
logic processor runs control logic which controls steps, transitions,
processor input interrupts, selectable timed interrupts, and
independent background programs.
CAR refers to the type of file; 0 refers to the program file number into
which the CAR will be downloaded.
The system returns to the Program Directory.