Configuring or editing steps – Rockwell Automation D64046.5.1 U MNL WIN DDMC User Manual

Page 59

Advertising
background image

Configuring SDS Instructions

Chapter 4

4-23

You can perform the following functions from the Step Directory:

If you want to:

Press this key:

Change between remote/run program mode
and test mode.

[F1] - Change Mode

Update the internal SDS data base
documentation for diagnostic messages.

[F2] - Update Msg DB

Exit the configuration utility. (This key is
active only when the Step Directory is your
point of entry into the SDS instruction.)

[F3] - Exit

Configure or edit your combinatorial or
transitional equations

[F5] - Edit Step

Display the Extended Edit screen.

[F6] – Extnded Edit

Display the I/O Monitor screen. (Refer to
Chapter 8 - “Debugging Your DDMC32
System” for information on the I/O Monitor
screen.)

[F8] - I/O Monitor

Accept all entries/edits. The system prompts
you to confirm your decision.

[F10] - Accept Edits

Display error list.

1

[F9] -Display Err Lst

1

[F9] is displayed only as a result of pressing [F10] - Accept Edits when errors exist in the

configuration.

Configuring or Editing Steps

From the Step Directory, cursor to the appropriate step and press

[F5] - Edit Step

(you cannot edit Step 0). You see the Edit Step screen as

shown below.

Edit Step screen (PLC-5)

STEP 1 LOADING TIMER=5.00s STEP 11 MSG:ON

No Input ID Equation Destination No Output ID State

0 PART IN POSITION ON –> OFF **STEP 2 1 VALVE 4 OFF

1 CLAMP LS1 2 CLAMPS OPEN ON

2 CLAMP LS2 3 CLAMPS CLOSED OFF

3 CLAMP LS3 4 SOLENOID LAST

4 CLAMP LS4 5 LIGHT LAST

5 HAND 6 MOTOR 2 ON

6 AUTO

7 JOG PB

8 PERMISSIVE

Press a function key.

Enter destination step number or ’INIT’ >

Prog edit mode 5/25 Addr 5 SDSTEST

Equatn Display Step Step Edit Step Msg Equatn Output Marked

List Symbol Name Type Step Timer Off Editor State Exit

F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Advertising