Chapter 8
Debugging Your DDMC32 System
8-11
Sample Extended Status Screen for an SDS Instruction
Timed out: 0 TO (bit 8) SDS is enabled: 1 EN
To be retried: 0 NR (bit 9) Runtime error: 0 ER
Awaiting execution: 0 EW (bit 10) Program error step: 0 ES
Continuous: 0 CO (bit 11) Input mismatch active: 0
Error: 1 ER (bit 12) Step timer enabled: 0 TE
Message done: 0 DN (bit 13) Step timer (accum): 0.0
Message transmitting: 0 ST (bit 14) Enabled inputs (15–0): 1000 0111 1111 1111
Message enabled: 0 EN (bit 15)
Message type: Error message
Last step: 6 – ADVANCING SLIDE
Input ID: 2 I:006/01 Input state: ON
Press a function key.
RUN monitor mode Current Step 13 PLC–5/12 Addr 4
Display
Comment
F2
Message Instruction (MSG)
Status Information
(For information about
this instruction, Refer to
PLC-5 Family Programmable
Controllers Processor
Manual (publication
1785-6.8.2)
SDS Instruction
output bits
The extended status screen for the DFA instruction is somewhat different
from that of the SDS instruction. The following figure shows an example
of an Extended Status screen for a DFA instruction.