Auxiliary control power specifications – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual
Page 156
Advertising
Publication 2093-UM001A-EN-P — March 2007
156
Specifications and Dimensions
Auxiliary Control Power Specifications
This section lists auxiliary control power requirements for a Kinetix 2000
system comprised of an IAM, up to seven AMs, a Shunt Module, or a Slot
Filler.
Auxiliary Control Power Specifications
Number of AMs
(2093-AMPx or
2093-AMx)
Current Requirements
(115V ac)
Current Requirements
(230V ac)
Max Inrush
Input VA
0
0.3 A
0.15 A
93 A
50 VA
1
0.6 A
0.30 A
99 VA
2
0.9 A
0.45 A
148 VA
3
1.2 A
0.60 A
197 VA
4
1.5 A
0.75 A
247 VA
5
1.8 A
0.90 A
296 VA
6
2.1 A
1.05 A
345 VA
7
2.4 A
1.20 A
395 VA
Shunt Module
(2093-ASP06)
2.5 A
1.25 A
410 VA
Slot Filler
(2093-PRF)
— — — —
Advertising