Control power input, Important – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual
Page 55
 
Publication 2093-UM001A-EN-P — March 2007
Kinetix 2000 Connector Data
55
Brake Relay Circuit
(1)
Noise suppression device.
Brake Relay Output Specifications
Control Power Input
The integrated axis module (IAM) requires ac input power for logic circuitry.
Control Power Current Specifications
Control Power Current Requirements
PWR
(BC-1)
BRK-
(BC-3)
BRK+
(BC-2)
COM
(BC-4)
(1)
Kinetix 2000 IAM/AM
Parameter
Description
IAM/AM
Max
On-state current
(1)
(1)
For motors requiring more than the maximum current specified, an external relay must be added. Refer to the 
Wiring Example for External Brake Relay Control of Motor Brake on page 182 for a diagram of this circuit. 
Current flow when the 
relay is closed
2093-AC05-MPx
1.0 A
2093-AMPxx
2093-AMxx
On-state resistance
Contact resistance when the relay is closed
1
Ω
Off-state voltage
Voltage across the contacts when the relay is open
30V
IMPORTANT
For CE certification, the control power input requires an ac line filter 
that provides electromagnetic compatibility (EMC). For wiring 
examples, refer to Power Wiring Examples beginning on page 169. 
IMPORTANT
Source 2093-AC05-MPx (230V) IAM control power from the 
three-phase input power (line-to-line). Supplying 230V control power 
from any other source requires an isolation transformer. If used, do 
not ground either leg of the isolation transformer output. 
Refer to Transformer Specifications for Control Power Input on page 
159. 
Attribute Value
Input voltage
170...264V ac rms, 
single-phase or three-phase 
Input power frequency
47...63 Hz