Power dissipation specifications – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual
Page 160

Publication 2093-UM001A-EN-P — March 2007
160
Specifications and Dimensions
Power Dissipation
Specifications
Use the following table to size an enclosure and calculate required ventilation
for your Kinetix 2000 system.
Kinetix 2000 Modules
Usage as a Percentage of Rated Power Output (Watts)
20%
40%
60%
80%
100%
Converter (IAM)
(1)
2093-AC05-MP1
Three-phase
7.0 10.5 14.0 17.4 20.9
2093-AC05-MP2
2093-AC09-MP5
2093-AC05-MP1
Single-phase
5.8 8.0 10.3 12.6 14.8
2093-AC05-MP2
2093-AC09-MP5
Inverter (IAM and AM)
(1)
2093-AC05-MP1
and
2093-AMP1
31.6 33.6 35.6 37.6 39.6
2093-AC05-MP2
and
2093-AMP2
33.0 36.4 39.8 43.3 46.8
2093-AC05-MP5
and
2093-AMP5
36.2 42.9 49.8 56.8 63.9
2093-AM01
38. 3
46.7
55. 3
64. 1
73. 1
2093-AM02 44.
3
55.6
67.
3
79.2
91.4
Shunt module (SM)
2093-ASP06
35.8 45.8 55.8 65.8 75.8
Power Rail
2093-PRSxx
0 0 0 0 0
Connector Kit
2093-K2CK-D15M
0 0 0 0 0
(1)
Internal shunt power is not included in the calculations and must be added based on utilization.