Wiring 15-pin panel-mounted breakout kit, Wiring 44-pin panel-mounted breakout kit, Important – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual
Page 97
 
Publication 2093-UM001A-EN-P — January 2007
Connecting the Kinetix 2000 Drive System
97
Wiring 15-pin Panel-mounted Breakout Kit
A panel-mounted breakout kit, catalog number 2090-UXBK-D15xx, is 
available. This kit permits connection between a motor feedback device and 
the motor feedback (MF) connector. A cable connects between a 
panel-mounted terminal block and the 15-pin motor feedback (MF) 
connector. Wires from an external motor feedback device interface via the 
panel-mounted terminal block. 
15-pin and 44-pin Breakout Kits for Use with Kinetix2000 Drives
Wiring 44-pin Panel-mounted Breakout Kit
A panel-mounted breakout kit, catalog number 2090-U3BK-D44, is available. 
This kit permits connection between external devices and the input/output 
and auxiliary feedback (IOD/AF) connector. A cable connects between a 
panel-mounted terminal block and the 44-pin I/O and auxiliary feedback (IO/
AF) connector. Wires from external devices interface via the panel-mounted 
terminal block. 
Kinetix2000 Drive
(2093-AC05-MP
x
is shown)
2090-U3BC-D44
xx
Breakout Cable
44 pin
I/O and Auxiliary
Feedback
Connector
2090-U3BB-D44
Panel-mounted 
Terminal Block
Wire Terminations
15 pin
Motor
Feedback
Connector
2090-UXBB-D15
Panel-mounted 
Terminal Block
Wire
Terminations
2090-UXBC-D15
xx
Breakout Cable
IMPORTANT
The 15-pin and 44-pin breakout blocks accept wire in the range of 
4…0.14 mm
2
(12…26 AWG).