These tables list the system components and accessory items available for the Kinetix 6000M IDM drive systems.

Kinetix 6000M Integrated Drive-Motor (IDM) Units

Kinetix 6000M IDM Power Interface Module (IPIM)

Refer to the Kinetix Rotary Motion Technical Data, publication

GMC-TD001

, for detailed descriptions and additional

specifications for the Kinetix 6000M integrated drive-motor (IDM) units and IPIM module.

Required Hybrid Cables

Refer to the Kinetix Motion Accessories Technical Data, publication

GMC-TD004

, for detailed descriptions and

specifications of these required accessories.

Cat. No.

Speed

Continuous Torque

Peak Torque

Features

Quantity

MDF-SB1003P

5000 rpm

3.0 N•m (26.5 lb•in)

10.5 N•m (92.9 lb•in)

USDA compliant

food-grade paint

400V-class
Safe-off

Up to 16 on each IPIM module

(1)

(1) Use Motion Analyzer software, version 6.00 or later, to determine the maximum number of IDM units to daisy-chain on each IPIM module.

MDF-SB1153H

3500 rpm

4.8 N•m (42.5 lb•in)

18.5 N•m (164 lb•in)

MDF-SB1304F

3000 rpm

7.25 N•m (64.2 lb•in)

21.75 N•m (192 lb•in)

Cat. No.

Output Bus Voltage

Continuous Output

Peak Output

Slot Usage

Quantity

2094-SEPM-B24-S

650V DC

15 kW, 24 A, rms

60 A

1

Up to 4 on each power rail

(1)

(1) Use Motion Analyzer software, version 6.00 or later, to determine the maximum number of IPIM modules on a single power rail.

Cat. No.

Description

Cable Configuration

Quantity

Flying-lead/Pin

Socket

2090-CHBIFS8-12AAxx

(1)

(1) Cables are available in standard lengths of 1, 2, 3, 4, 5, 7, 9, 12, 15, 20, and 25 m (3.2, 6.6, 9.8, 13.1, 16.4, 22.9, 29.5, 39.3, 49.2, 65.5, and 82.0 ft).

From IPIM module (flying-leads) to the first IDM unit
IPIM-end flying-leads (IF)
SpeedTec connector, socket (S8)

1 required per system (IPIM
module to first IDM unit)

2090-CHBP8S8-12AAxx

(2)

(2) Cables are available in standard lengths of 0.5, 1, 2, 3, 4, 5, 7, 9, 12, 15, 20, and 25 m (1.6, 3.2, 6.6, 9.8, 13.1, 16.4, 22.9, 29.5, 39.3, 49.2, 65.5, and 82.0 ft).

IDM unit-to-unit connections
SpeedTec connector, pin (P8)
SpeedTec connector, socket (S8)

1 required for the second IDM
unit and each additional
downstream IDM unit

2090-CTHP8

Hybrid (SpeedTec) terminator
Required on last IDM unit, pin (P8)
Included with each IPIM module

1 required per system