Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual

Page 107

Advertising
background image

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013

107

Kinetix 6000 and Kinetix 6200/6500 Drive Systems

Kinetix 6000 (200V-class) Drives/LDC-Series Linear Motor Curves (continued)

2094-AM03-S and LDC-C100300-DHT

2094-AM01-S and LDC-C100300-EHT

Force

(N)

Force

(lb)

Velocity (m/s)

3

2

0

4

1

Water Cooling

2000
1750
1500
1250
1000

750
500
250

0

450
393
337
281
225
169
112
56.0
0

Air Cooling

No Cooling

2500

2000

1500

1000

500

0

562

450

337

225

112

0

2094-AM03-S and LDC-C100400-DHT

2094-AM02-S and LDC-C100400-EHT

Force

(N)

Force

(lb)

Velocity (m/s)

3

2

0

4

1

Water Cooling

Air Cooling
No Cooling

2094-AM05-S and LDC-C100600-DHT

Force

(N)

Force

(lb)

Velocity (m/s)

3

2

0

4

1

Water Cooling

4000
3500
3000
2500
2000
1500
1000

500

0

899
787
674
562
450
337
225
112
0

Air Cooling
No Cooling

2094-AM03-S and LDC-C150400-DHT

Force

(N)

Force

(lb)

4000
3500
3000
2500
2000
1500
1000

500

0

899
787
674
562
450
337
225
112
0

Velocity (m/s)

0.5

2

1.5

0

3

2.5

1

Water Cooling

Air Cooling
No Cooling

Velocity (m/s)

0.5

2

1.5

0

3

2.5

1

2094-AM05-S and LDC-C150600-DHT

Force

(N)

Force

(lb)

Water Cooling

No Cooling

6000

5000

4000

3000

2000

1000

0

1349

1124

899

674

450

225

0

Air Cooling

= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region

Advertising