60

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013

Kinetix 6000 and Kinetix 6200/6500 Drive Systems

Kinetix 6000 and Kinetix 6200/6500 (400V-class) Drives with RDD-Series Motor Curves (continued)

Torque

(N•m)

Torque

(lb•in)

2094-BM05-S @ 200% or 2094-BM05-M

and RDB-B29036

Speed (rpm)

600

200

1000

442

885

1328

1770

2213

2655

0

50

100

150

200

250

300

350

3098

0

400

800

Torque

(N•m)

Torque

(lb•in)

2094-BM03-S @ 250% or 2094-BM03-M

and RDB-B29034

Speed (rpm)

0

200

400

300

100

500

442

885

1328

1770

2213

2655

0

50

100

150

200

250

300

350

3098

0

Torque

(N•m)

Torque

(lb•in)

2094-BM05-S @ 200% or 2094-BM05-M

and RDB-B41016

Speed (rpm)

0

400

800

600

200

1000

442

885

1328

1770

2213

2655

0

50

100

150

200

250

300

350

3098

0

Torque

(N•m)

Torque

(lb•in)

0

0

70

140

210

350

280

619

1239

1859

2478

3098

2094-BM03-S @ 250% or 2094-BM03-M

and RDB-B41014

Speed (rpm)

0

200

400

300

100

500

Torque

(N•m)

Torque

(lb•in)

2094-BM05-S @ 200% or 2094-BM05-M

and RDB-B41024

Speed (rpm)

0

200

400

300

100

500

885

1770

2655

3540

4425

5310

0

100

200

300

400

500

600

700

6195

0

= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC rms input voltage