Digital input cable examples – Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual

Page 12

Advertising
background image

12

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013

Kinetix 6000 and Kinetix 6200/6500 Drive Systems

Digital Input Cable Examples

Kinetix 6000M IDM units have three 5-pin, M12, digital input connectors. Allen-Bradley (Bulletin 889D and 879D)
DC micro-style patchcords, splitters, and V-cables are available with straight and right-angle connectors for making
connections from the IDM unit to input sensors.

For the most popular patchcord specifications, refer to the Connection Systems Quick Selection Guide, publication

CNSYS-BR001

. For complete information, refer to On-Machine™ Connectivity, publication

M117-CA001

.

Digital Inputs Used for Home and Overtravel Functions

Digital Input Accessories Items

Cat. No.

Item Type

Description

Cable Configuration

Socket

Pin (IDM unit)

889D-F4ACDM-x

Digital input patchcords

(1)

(IDM unit to NC and NO sensors)

(1) Patchcords are available in standard lengths of 2, 5, and 10 m (6.6, 16.4, and 32.8 ft).

Straight connector, socket (F)
Straight connector, pin (M)

889D-R4ACDM-x

Right-angle connector, socket (R)
Straight connector, pin (M)

889D-F4ACDE-x

Straight connector, socket (F)
Right-angle connector, pin (E)

889D-R4ACDE-x

Right-angle connector, socket (R)
Right-angle connector, pin (E)

871TS-N12BP18-D4

Sensor (example)

Proximity

N/A

889D-x4ACDx-x

Patchcords

Input Assignments:
1 = Overtravel- (NC)
2 = Overtravel+ (NC)
3 = Home (NO)

Digital Inputs

(1, 2, 3)

Input Assignments:
1 = Registration 2 (NO)
2 = Registration 1 (NO)

MDF-SBxxxxx

IDM Units

Sensors

1 2 3

1 2

Advertising