Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual

Page 67

Advertising
background image

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013

67

Kinetix 6000 and Kinetix 6200/6500 Drive Systems

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

Performance Specifications with Frame 70 Linear Thrusters

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

LDAT-S053010-DBx

4.1

9.4

378 (85)

34.2

1093 (246)

1.31

2094-AM02-S

LDAT-S053020-DBx

5.0

1.53

LDAT-S053030-DBx

LDAT-S053050-DBx

5.0

1.53

LDAT-S053010-EBx

LDAT-S053050-EBx

1.7

3.1

11.4

0.47

2094-AMP5-S

LDAT-S054010-DBx

4.4

12.4

509 (114)

45.5

1453 (327)

1.87

2094-AM02-S

LDAT-S054020-DBx

LDAT-S054050-DBx

5.0

2.05

LDAT-S054010-EBx

LDAT-S054050-EBx

2.6

6.2

22.7

1.02

2094-AM01-S

Linear Thruster
Cat. No.

Velocity, max
230V AC
m/s

System Continuous
Stall Current
Amps 0-pk

System Continuous
Stall Force
N (lb)

System Peak
Stall Current
Amps 0-pk

System Peak
Stall Force
N (lb)

Rated Output
230V AC
kW

Kinetix 6000
200V-class Drives

LDAT-S072010-DBx

LDAT-S072070-DBx

3.5

6.0

364 (82)

22.0

1055 (237)

1.03

2094-AM01-S

LDAT-S072010-EBx

LDAT-S072070-EBx

1.7

3.0

11.0

0.47

2094-AMP5-S

LDAT-S073010-DBx

LDAT-S073070-DBx

3.5

9.0

554 (125)

32.8

1576 (354)

1.57

2094-AM02-S

LDAT-S073010-EBx

LDAT-S073070-EBx

1.2

3.0

10.9

0.41

2094-AMP5-S

LDAT-S074010-DBx

LDAT-S074070-DBx

3.5

11.9

730 (164)

43.5

2088 (469)

2.08

2094-AM02-S

LDAT-S074010-EBx

LDAT-S074070-EBx

1.8

6.0

21.7

0.95

2094-AM01-S

LDAT-S076010-DBx

LDAT-S076070-DBx

3.5

18.2

1122 (252)

66.4

3189 (717)

3.17

2094-AM03-S

LDAT-S076010-EBx

LDAT-S076070-EBx

1.8

9.1

33.2

1.45

2094-AM02-S

Performance Specifications with Frame 50 Linear Thruster (continued)

Linear Thruster
Cat. No.

Velocity, max
230V AC
m/s

System Continuous
Stall Current
Amps 0-pk

System Continuous
Stall Force
N (lb)

System Peak
Stall Current
Amps 0-pk

System Peak
Stall Force
N (lb)

Rated Output
230V AC
kW

Kinetix 6000
200V-class Drives

Advertising