Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual

Page 111

Advertising
background image

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013

111

Kinetix 6000 and Kinetix 6200/6500 Drive Systems

Kinetix 6000 and Kinetix 6200/6500 (400V-class) Drives/LDC-Series Linear Motor Curves

200

160

120

80

40

0

45.0

36.0

27.0

18.0

9.0

0

2094-BM01-S @ 150% or 2094-BM01-M

and LDC-C030100-DHT

Force

(N)

Force

(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling
No Cooling

Intermittent curve represents

460V and 400V inputs

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2094-BM02-S @ 250% or 2094-BM02-M

and LDC-C030200-DHT

Force

(N)

Force

(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling
No Cooling

Intermittent curve represents

460V and 400V inputs

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2094-BM01-S @ 150% or 2094-BM01-M

and LDC-C030200-EHT

Force

(N)

Force

(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling
No Cooling

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2094-BM01-S @ 150% or 2094-BM01-M

and LDC-C050100-DHT

Force

(N)

Force

(lb)

Water Cooling

Air Cooling
No Cooling

Velocity (m/s)

2

8

6

0

12

10

4

800

640

480

320

160

0

180

144

108

72.0

36.0

0

2094-BM02-S @ 250% or 2094-BM02-M

and LDC-C050200-DHT

Force

(N)

Force

(lb)

Water Cooling

Air Cooling
No Cooling

Velocity (m/s)

2

8

6

0

12

10

4

800

640

480

320

160

0

180

144

108

72.0

36.0

0

2094-BM01-S @ 150% or 2094-BM01-M

and LDC-C050200-EHT

Force

(N)

Force

(lb)

Velocity (m/s)

6

4

0

8

2

Water Cooling

Air Cooling
No Cooling

= Intermittent operating region
= Intermittent operating region with 400V AC rms input voltage
= Continuous operating region

Advertising