Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual

Page 96

Advertising
background image

96

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013

Kinetix 6000 and Kinetix 6200/6500 Drive Systems

Kinetix 6000 and Kinetix 6200/6500 Drives/MP-Series Electric Cylinder Curves

500

400

300

200

100

0

112

89.9

67.4

45.0

22.5

0

Velocity (mm/s)

150

100

0

200

50

2094-AMP5-S and MPAR-A1xxxB-VxA

2094-BMP5-S @ 150% or 2094-BMP5-M

and MPAR-B1xxxB-VxA

Force

(N)

Force

(lb)

500

400

300

200

100

0

112

89.9

67.4

45.0

22.5

0

2094-AMP5-S and MPAR-A1xxxE-VxA

2094-BMP5-S @ 150% or 2094-BMP5-M

and MPAR-B1xxxE-VxA

Force

(N)

Force

(lb)

Velocity (mm/s)

100

400

300

0

600

500

200

2094-AMP5-S and MPAR-A2xxxC-VxA

2094-BMP5-S @ 150% or 2094-BMP5-M

and MPAR-B2xxxC-VxA

Force

(N)

Force

(lb)

Velocity (mm/s)

50

200

150

0

300

250

100

22.5

45.0

67.4

89.9

112

135

0

100

200

300

400

500

600

700

157

0

1000

800

600

400

200

0

Velocity (mm/s)

600

400

0

800

200

2094-AM01-S and MPAR-A2xxxF-VxA

2094-BMP5-S @ 150% or 2094-BMP5-M

and MPAR-B2xxxF-VxA

Force

(N)

Force

(lb)

225

180

135

89.9

45.0

0

500

300

700

100

2094-AM02-S and MPAR-A3xxxE-MxA

2094-BM01-S @ 150% or 2094-BM01-M

and MPAR-B3xxxE-MxA

Force

(N)

Force

(lb)

Velocity (mm/s)

100

400

300

0

600

500

200

3000

2400

1800

1200

600

0

674

540

405

270

135

0

2000

1600

1200

800

400

0

450

360

270

180

89.9

0

2094-AM02-S and MPAR-A3xxxH-MxA

2094-BM01-S @ 150% or 2094-BM01-M

and MPAR-B3xxxH-MxA

Force

(N)

Force

(lb)

Velocity (mm/s)

200

800

600

0

1200

1000

400

= Intermittent operating region
= Continuous operating region

Advertising