Kinetix 6000 and kinetix 6200/6500 drive systems, Determine what you need – Rockwell Automation 2094-xxxx Kinetix 6000 and Kinetix 6200/6500 Drive Systems Design Guide User Manual

Page 3

Advertising
background image

Rockwell Automation Publication GMC-RM003C-EN-P - September 2013

3

Kinetix 6000 and Kinetix 6200/6500 Drive Systems

Kinetix 6000 and Kinetix 6200/6500 Drive Systems

For each Kinetix 6000, Kinetix 6200, or Kinetix 6500 drive system, you need to know the drive and motor/actuator catalog
numbers to determine the motor power and feedback cable catalog numbers. Interface cables, connector kits, and a Bulletin
2094 power rail are also required. Optional equipment includes the 2094 shunt module, slot-filler modules, line interface
module, AC line filter, and others. Example diagrams of the required equipment listed on this page are shown on

page 5

.

For Kinetix 6000M integrated drive-motor system information including cables and torque/speed curves, refer to

page 9

.

For Kinetix 6000 and Kinetix 6200/6500 (rotary motion) system combinations, refer to

page 17

. For linear motion system

combinations, refer to

page 86

.

Determine What You Need

These tables list the drive modules and accessory items available for the Kinetix 6000 and Kinetix 6200/6500 drive systems.

Kinetix 6000 Drive Modules

Refer to the Kinetix Servo Drives Technical Data, publication

GMC-TD003

, for detailed descriptions and additional

specifications for the Kinetix 6000 drive family.

Drive Module

Drive Cat. No.

(1)

(1) The -S designator indicates safe-off functionality.

Continuous Output Ratings

Slot Usage

Quantity

Converter (A

DC

)

Inverter (A, 0-pk)

Integrated axis module
(IAM) 200V-class

2094-AC05-MP5-S

3 kW, 10 A

1.2 kW, 5 A

Single wide

1 for each power rail

2094-AC05-M01-S

3 kW, 10 A

1.9 kW, 9 A

2094-AC09-M02-S

6 kW, 19 A

3.4 kW, 15 A

2094-AC16-M03-S

11.3 kW, 36 A

5.5 kW, 25 A

2094-AC32-M05-S

22.5 kW, 71 A

11.0 kW, 49 A

Double wide

Integrated axis module
(IAM) 400V-class

2094-BC01-MP5-S

6 kW, 9 A

1.8 kW, 4.0 A

Single wide

2094-BC01-M01-S

6 kW, 9 A

3.9 kW, 8.6 A

2094-BC02-M02-S

15 kW, 23 A

6.6 kW, 14.6 A

2094-BC04-M03-S

28 kW, 42 A

13.5 kW, 30 A

Double wide

2094-BC07-M05-S

45 kW, 68 A

22.0 kW, 49 A

Axis module (AM)
200V-class

2094-AMP5-S

N/A

1.2 kW, 5 A

Single wide

Up to 7 for each 8-axis power rail

2094-AM01-S

1.9 kW, 9 A

2094-AM02-S

3.4 kW, 15 A

2094-AM03-S

5.5 kW, 25 A

2094-AM05-S

11.0 kW, 49 A

Axis module (AM)
400V-class

2094-BMP5-S

N/A

1.8 kW, 4.0 A

Single wide

Up to 7 for each 8-axis power rail

2094-BM01-S

3.9 kW, 8.6 A

2094-BM02-S

6.6 kW, 14.6 A

2094-BM03-S

13.5 kW, 30 A

Double wide

Up to 3 for each 8-axis power rail

2094-BM05-S

22.0 kW, 49 A

Advertising