Kinetix 6000 and Kinetix 6200/6500 Drive Systems

LDC-Series Performance Specifications with Kinetix 6000 (200V-class) Drives (continued)

Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.

Kinetix 6000 (200V-class) Drives/LDC-Series Linear Motor Curves

Linear Motor

Speed, max
m/s (ft/s)

System Continuous
Stall Current

(1)

Amps 0-pk

(1) Values represent the range between no cooling (low value) and water cooling (high value).

System Continuous
Stall Force

(1)

N (lb)

System Peak
Stall Current
Amps 0-pk

System Peak
Stall Force
N (lb)

Linear Motor
Rated Output
kW

Kinetix 6000
200V-class Drives

LDC-C075200-DHT

10.0 (32.8)

7.7…11.5

348…523 (78…117)

22.9

882 (198)

1.74…2.61

2094-AM02-S

LDC-C075200-EHT

3.8…5.7

11.5 2094-AMP5-S

LDC-C075300-DHT

11.5…17.2

523…784 (117…176)

35.6

1368 (308)

2.61…3.92

2094-AM03-S

LDC-C075300-EHT

3.8…5.7

11.9 2094-AM01-S

LDC-C075400-DHT

15.3…23.0

697…1045
(157…235)

47.4

1824 (410)

3.48…5.22

2094-AM03-S

LDC-C075400-EHT

7.7…11.5

23.7 2094-AM02-S

LDC-C100300-DHT

10.0 (32.8)

11.1…16.7

674…1012
(152…227)

34.3

1767 (397)

3.37…5.06

2094-AM03-S

LDC-C100300-EHT

3.7…5.6

11.4

2094-AM01-S

LDC-C100400-DHT

14.8…22.2

899…1349
(202…303)

45.7

2356 (530)

4.49…6.74

2094-AM03-S

LDC-C100400-EHT

7.4…11.1

22.8

2094-AM02-S

LDC-C100600-DHT

22.2…33.3

1349…2023
(303…455)

68.5

3534 (794)

6.74…10.11

2094-AM05-S

LDC-C150400-DHT

10.0 (32.8)

14.1…21.1

1281…1922
(288…432)

45.2

3498 (786)

6.40…9.61

2094-AM03-S

LDC-C150600-DHT

21.1…31.7

1922…2882
(432…648)

67.8

5246 (1179)

9.61…14.41

2094-AM05-S

200

160

120

80

40

0

45.0

36.0

27.0

18.0

9.0

0

2094-AM01-S and LDC-C030100-DHT

Force

(N)

Force

(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling
No Cooling

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2094-AM02-S and LDC-C030200-DHT

2094-AM01-S and LDC-C030200-EHT

Force

(N)

Force

(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling
No Cooling

= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region

Advertising