Appendix a, Ppendix, Sa3100 vector regulator register reference – Rockwell Automation SA3100 Distributed Power System Drv Config,Program User Manual

Page 117

Advertising
background image

SA3100 Vector Regulator Register Reference

A-1

A

PPENDIX

A

SA3100 Vector Regulator

Register Reference

REGISTER MAP

Registers

Function

0-23

Flex I/O port registers

24-79

System Use Only

80-89

UDC/PMI comm. status registers for drive A

90-99

System Use Only

100-106

Command registers for drive A

107-199

System Use Only

200-222

Feedback registers for drive A

223-299

System Use Only

300-599

Application registers updated every scan
for drives A and B

600-999

System Use Only

1000

UDC module test switch register

1001-1017

UDC module meter port setup registers

1018-1079

System Use Only

1080-1089

UDC/PMI comm. status registers for drive B

1090-1099

System Use Only

1100-1106

Command registers for drive B

1107-1199

System Use Only

1200-1222

Feedback registers for drive B

1223-1299

System Use Only

1300-1599

Application registers updated every scan
for drives A and B

1600-1999

System Use Only

2000-2010

Interrupt Status and Control registers for
drives A and B

2011-2047

System Use Only

REGISTER/BIT DESCRIPTIONS

FLEX I/O PORT REGISTERS

A / B
0 / 12

PMI Module 0, Digital I/O

1 / 13

PMI Module 1, Digital I/O

2 / 14

PMI Module 2, Digital or Analog I/O

3 / 15

PMI Module 2, Analog 1 I/O

4 / 16

PMI Module 2, Analog 2 I/O

5 / 17

PMI Module 2, Analog 3 I/O

6 / 18

PMI Module 2, Analog 4 I/O

7 / 19

PMI Module 2, Analog 5 I/O

8 / 20

PMI Module 2, Analog 6 Input

9 / 21

PMI Module 2, Analog 7 Input

10 / 22

Flex System Fault Bits, PMI Module 0 & 1 Faults
Bit
0 Flex Bus Fault
1 Flex Clock Fault
2 Flex Scratch Pad Fault
3 Flex Dual Port Fault
4 - 7 Not Used
8 Module 0 Not Plugged In
9 Module 0 Communication Error
10 Module 0 Bad ID
11 Module 0 Location Error
12 Module 1 Not Plugged In
13 Module 1 Communication Error
14 Module 1 Bad ID
15 Module 1 Location Error

FLEX I/O PORT REGISTERS (CONTINUED)

11 / 23

Flex Module 2 Fault Bits
Bit
0 Module 2 not plugged in
1 Module 2 communication error
2 Module 2 Bad ID code
3 - 7 Not Used
8 Channel 0 output open/input underrange
9 Channel 1 output open/input underrange
10 Channel 2 output open/input underrange
11 Channel 3 output open/input underrange
12 Channel 4 output open/input underrange
13 Channel 5 output open/input underrange
14 Channel 6 output open/input underrange
15 Channel 7 output open/input underrange

UDC-PMI COMMUNICATION STATUS

A/B
80 /1080 UDC Module port status

Bit
0 Invalid rcr interrupt
1 No end of frame status
2 CRC/framing error
3 Overrun error
4 DMA format error
5 Transmitter underrun
6 CCLK comm sync error
7 Loopback data error
8 Missed gains
9 Multiplexed data verification error
10 No matching PMI OS
11 Invalid PMI OS header
12 Incompatible PMI H/W

81 /1081 UDC module good msg. recvd. count
82 /1082 UDC module CRC error count
83 /1083 UDC module format error count
84 /1084 PMI port status

Bit
0 Invalid rcr interrupt
1 No end of frame status
2 CRC/framing error
3 Overrun error
4 DMA format error
5 Transmitter underrun
6 CCLK comm sync error
8 UDC CCLK comm sync error
9 Multiplexed data verification error
12 Invalid PMI start OS address
13 Insuff. PMI memory to load PMI OS
14 Invalid PMI load address
15 PMI OS overflow

85 /1085 PMI good msg. recvd. count
86 /1086 PMI CRC error count
87 /1087 PMI format error count
88 /1088 Comm/link status
89 /1089 UDC transmitted msg. count

COMMAND REGISTERS

A/B

100/1100 Drive Control

Bit
0 Enable PMI loop

PMI_RUN@

1 Enable tuning

PMI_TUN@

2 Bridge test enable

BRG_TST@

4 Bus enable

BUS_ENA@

5 DC braking on

BRK_ON@

6 Vector align request

VOA_REQ@

8 Fault reset

FLT_RST@

9 Warning reset

WRN_RST@

15 UDC task running (status)*

UDC_RUN@

101/1101 I/O Control

Bit
0 No slip adjustment

NO_ADJ@

1 No slip smoothing

NO_INTR@

2 External fault LED

EXT_LED@

4 Auxiliary output

AUX_OUT@

6 Enable resolver calibration

RES_CAL@

8 Enable external strobe

STR_ENA@

9 External strobe falling edge

STR_ENF@

10 STATOR_IZ_E1% tuning

TUN_IZ@

12 Torque overload ratio

TORD_ON@

15 UDC module loopback test

UDC_LB@

102/1102 Torque reference

TRQ_REF%

103/1103 <not used>
104/1104 Flux reference

FLX_REF%

Id reference (dual-wound motor) ID_REF%

105/1105 Bridge test code

TST_CODE%

106/1106 PMI D/A output

PMI_DA%

107/1107 <not used>

Vector orientatn ref (dual-wnd mtr)VO_REF%

108/1108 DC braking reference

BRK_REF%

109/1109 <not used>

FEEDBACK REGISTERS

A/B

200/1200 Drive status

Bit
0 Torque control on

TRQ_ON@

1 Auto tuning complete

PMI_ATC@

2 Torque ref saturation plus

TRF_SP@

3 Torque ref sat minus

TRF_SM@

4 DC bus ready

BUS_RDY@

5 Constant power region

PWR_RNG@

8 Fault detected

FLT@

9 Warning detected

WRN@

10 Vector align

WRN_VOA@

13 Flex I/O updated

(System use)

14 CCLK synchronized

CCLK_OK@

15 PMI OS loaded

PMI_OK@

201/1201 I/O status

Bit
0 Run permissive input

RPI@

1 M-contactor feedback

M_FDBK@

2 Auxiliary input 2

AUX_IN2@

3 Auxiliary input 3

AUX_IN3@

4 Auxiliary input 4

AUX_IN4@

5 Auxiliary input 5

AUX_IN5@

6 Resolver gain calibrated

RES_GAN@

7 Resolver balance calibrated

RES_BAL@

8 External strobe detected

STR_DET@

9 External strobe level

STR_LVL@

10 Stator IZ tuning complete

TUNED_IZ@

Advertising