C.3 Volts per Hertz Voltage Point Gain Variables

The seven gains below represent the seven voltage points of the V/Hz characteristic
curve. When the PMI Regulator detects a set of 0 value volts per hertz characteristic
gains it will calculate a curve.

When the enable tuning command (register 100/1100, bit 1, PMI_TUN@) is asserted,
these gains are reset to their default values. When the reset is complete register 200,
bit 1 (PMI_ATC@) is set.

See Appendix E (Figures E.2 and E.3) for more information on the V/Hz characteristic.

P0VT_E3!

Point 0 Voltage

This value is set to select the voltage at point 0
in the V/Hz characteristic curve.

This value is entered in times 1000, e.g., 50
volts is entered as 50000.

Units:

Volts

1000

Default Value:

0

Low Limit:

0

High Limit:

1000000

Step:

1

P1VT_E3!

Point 1 Voltage

This value is set to select the voltage at point 1
in the V/Hz characteristic curve.

This value is entered in times 1000, e.g., 50
volts is entered as 50000.

Units:

Volts

1000

Default Value:

0

Low Limit:

0

High Limit:

1000000

Step:

1

P2VT_E3!

Point 2 Voltage

This value is set to select the voltage at point 2
in the V/Hz characteristic curve.

This value is entered in times 1000, e.g., 50
volts is entered as 50000.

Units:

Volts

1000

Default Value:

0

Low Limit:

0

High Limit:

1000000

Step:

1

P3VT_E3!

Point 3 Voltage

This value is set to select the voltage at point 3
in the V/Hz characteristic curve.

This value is entered in times 1000, e.g., 50
volts is entered as 50000.

Units:

Volts

1000

Default Value:

0

Low Limit:

0

High Limit:

1000000

Step:

1

P4VT_E3!

Point 4 Voltage

This value is set to select the voltage at point 4
in the V/Hz characteristic curve.

This value is entered in times 1000, e.g., 50
volts is entered as 50000.

Units:

Volts

1000

Default Value:

0

Low Limit:

0

High Limit:

1000000

Step:

1

Advertising