3-44

SA3100 Drive Configuration and Programming

Interlock Register (Continued)

205/1205

MCR Did Not Close

Bit 7

The MCR Did Not Close bit is set if the
optional output contactor did not close when
commanded to do so.

Hex Value:

0080H

Sug. Var. Name:

IC_MCR@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Bit 8

Reserved for future use.

Hex Value:

0100H

Sug. Var. Name:
Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Bit 9

Reserved for future use.

.

Hex Value:

0200H

Sug. Var. Name:
Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Incompatible Resolver

Bit 10

The Incompatible Resolver bit is set if
Resolver & Drive I/O boards B/M 60001 or
B/M 60001-1 are detected in the PMI
Regulator.

Hex Value:

0400H

Sug. Var. Name:

IC_IRES@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

DC Bus Voltage (Volts) Register

206/1206

The DC Bus Voltage (Volts) register contains the voltage of the DC
bus. It is scaled in units of volts.

Sug. Var. Name:

BUS_VDC%

Units:

Volts

Range:

N/A

Access:

Read only

DC Bus Current (Amps) Register

207/1207

The DC Bus Current (Amps) register contains the measured current
in the DC bus. The value is scaled in amps times 10. For example,
50.1 amps would be represented as 501.

Sug. Var. Name:

BUS_IDC%

Units:

Amps

10

Range:

N/A

Access:

Read only