Dell PowerEdge VRTX User Manual

Page 180

Advertising
background image

180

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Dell Plasma\User

Guide\Plasma_UGSystemConfig.fm

D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 1 8 /1 3 - F O R P R O O F O N LY

–

User Name — The user to whom SNMP notifications are sent.

–

Security Level — The means by which the packet is authenticated.

The possible options are:
•

No Authentication — The packet is neither authenticated nor

encrypted.

•

Authentication — The packet is authenticated.

•

Privacy — The packet is both authenticated and encrypted.

3 Enter the fields for all versions of SNMP:

–

UDP Port (1-65535) — The UDP port used to send notifications. The

default is 162.

–

Filter Name — Select an SNMP filter from a list of previously-defined

SNMP filters.

–

Timeout (1-300) — The amount of time (seconds) the device waits

before resending informs.

–

Retries (1-255) — The amount of times the device resends an inform

request.

Advertising