Interval (1–2147483647) — Enter the alarm interval time in seconds.

This is the interval in seconds over which the data is sampled and

compared with the rising and falling thresholds.

Owner — Enter the name of the user or network management system

that receives the alarm.

Defining Device Alarms Using the CLI Commands

The following table contains the CLI commands for defining device alarms.

Table 18-10. Device Alarm CLI Commands

CLI Command

Description

rmon alarm index

MIB_Object_ID interval

rising-threshold falling-

threshold rising-event

falling-event [type

{absolute|delta}][startup

{rising|rising-

falling|falling}][owner

name]

no rmon alarm index

Configures RMON alarm conditions.
Use the no form of this command to

remove an alarm.

show rmon alarm-table

Displays summary of the alarm table.

show rmon alarm number

Displays the RMON alarm

configuration.