D E L L C O N F ID E N T IA L – P R E L IM I N A RY 4 / 1 8 /1 3 - F O R P R O O F O N LY
–
Interval (1–2147483647) — Enter the alarm interval time in seconds.
This is the interval in seconds over which the data is sampled and
compared with the rising and falling thresholds.
–
Owner — Enter the name of the user or network management system
that receives the alarm.
Defining Device Alarms Using the CLI Commands
The following table contains the CLI commands for defining device alarms.
Table 18-10. Device Alarm CLI Commands
CLI Command
Description
rmon alarm index
MIB_Object_ID interval
rising-threshold falling-
threshold rising-event
falling-event [type
{absolute|delta}][startup
{rising|rising-
falling|falling}][owner
name]
no rmon alarm index
Configures RMON alarm conditions.
Use the no form of this command to
remove an alarm.
show rmon alarm-table
Displays summary of the alarm table.
show rmon alarm number
Displays the RMON alarm
configuration.