Table 3-4 describes the major switch defaults:

Table 3-4. Major System Defaults

Feature

Defaults

SNMP

Enabled.
SNMP version: V3
SNMP Local Engine ID: 0000000001
SNMP Notifications: Enabled

Login and Authentication

Telnet authentication login is from the local

user data base
HTTP authentication login is from the

local data base
HTTPS authentication login is from the

local data base

Authentication Servers

No RADIUS server is defined
No TACACS server is defined

Logging

No SYSLOG server is defined

System Time

SNTP is supported

DHCP

DHCP server is disabled
DHCP auto configuration is enabled

Ports

24 GE regular ports
Full duplex is enabled.
Negotiation is enabled
Flow control is Off
No LAGs are defined

Multicast

Multicast filtering is disabled

IGMP Snooping

Disabled

Spanning Tree

Enabled

VLANs

Default VLAN is enabled
Default VLAN ID is 1

IP Addressing

IP address is 192.168.2.1