Sflow polling-interval (global version) – Dell POWEREDGE M1000E User Manual
Page 236
220
Dell Converged Enhanced Ethernet Command Reference
53-1002115-01
sflow polling-interval (global version)
13
sflow polling-interval (global version)
Configures the polling interval globally.
Synopsis
sflow polling-interval interval value
no sflow polling-interval
Operands
interval value
Specifies a value in seconds to set the polling interval. The range of valid
values is 1-65535.
Defaults
The default global counter polling interval value is 20 seconds.
Command
Modes
Global configuration mode
Description
Use this command to configure the polling interval globally. The interval is the maximum number of
seconds between successive samples of counters to be sent to the collector.
Use the no sflow polling interval interval command to return to the default value.
Usage
Guidelines
There are no usage guidelines for this command.
Examples
To set the polling interval to 135 seconds:
switch(config)#sFlow polling interval 135
See Also
sflow polling interval (interface version)