Show logging – Dell POWEREDGE M1000E User Manual
Page 46
30
Dell Converged Enhanced Ethernet Command Reference
53-1002115-01
show logging
2
show logging
Displays the internal syslog buffer of the switch.
Synopsis
show logging
Operands
none
Defaults
There are no default configurations for this command.
Command
Modes
Privileged EXEC mode
Description
Use this command to display the RASlog messages stored in the internal buffer.
Usage
Guidelines
The RASlog messages contain the module name, error code, and message details.
Examples
To display the syslog messages stored in the internal buffer:
switch#show logging
Fabos OS Version: v6.1.2
Number of Messages: 1024
2009/02/03-00:19:43: %NSM-4-1001: Interface InTenGigabitEthernet 0/4 is
online.
2009/02/03-00:20:14: %NSM-4-1002: Interface InTenGigabitEthernet 0/4 is
protocol down.
2009/02/03-00:20:14: %NSM-4-1001: Interface InTenGigabitEthernet 0/4 is
online.
2009/02/03-00:21:10: %NSM-4-1003: Interface Port-channel 10 is link down
See Also