Dell POWEREDGE M1000E User Manual

Page 83

Advertising
background image

Dell Converged Enhanced Ethernet Command Reference

67

53-1002115-01

show interface

4

Errors: 0, Discards: 0

Transmit Statistics:

0 packets, 0 bytes

Unicasts: 0, Multicasts: 0, Broadcasts: 0

Underruns: 0

Errors: 0, Discards: 0

Rate info (interval 299 seconds):

Input 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate

Output 0.000000 Mbits/sec, 0 packets/sec, 0.00% of line-rate

Time since last interface status change: 00:02:17

To display Layer 2 information for all interfaces:

switch#show interface switchport

Interface name : InTenGigabitEthernet 0/8

Switchport mode : access

Ingress filter : enable

Acceptable frame types : all

Default Vlan : 1

Active Vlans : 1

Inactive Vlans : -

Interface name : ExTenGigabitEthernet 0/19

Switchport mode : hybrid

Ingress filter : enable

Acceptable frame types : all

Default Vlan : 1

Active Vlans : 1

Inactive Vlans : 100

Interface name : ExTenGigabitEthernet 0/20

Switchport mode : trunk

Ingress filter : enable

Acceptable frame types : vlan-tagged only

Default Vlan : 0

Active Vlans : 1

Inactive Vlans : -

See Also

show ip interface

Advertising