E LT-9001-IM

7-9

Timing Chart

The timing charts in the normal measurement and in the profile data output are as follows.

Normal/Auto peak hold/Auto bottom hold/Auto peak-to-peak hold

•

The minimum input time (T1), sampling cycle (T2), scanning change time (T3), RESET time (T4), and

update cycle (T5) vary according to the settings.

Refer to "Timing Details" (page 7-13) for details.

•

T3 is required only when the scanning setting is to be changed.

•

Stability output is always output in a sampling cycle (T2).

Peak hold/Bottom hold/peak-to-peak hold/average hold/sample hold

•

The minimum input time (T1), sampling cycle (T2), scanning change time (T3), and RESET time(T4) vary

according to the settings.

Refer to "Timing Details" (page 7-13) for details.

•

With RESET input, the internal measured value is fixed after the RESET time has elapsed.

•

T3 is required only when the scanning setting is to be changed.

•

STABILITY output is always output in a sampling cycle (T2).

Normal Measurement (When Profile Output is OFF)

MinT1