Setting the light intensity level, Measuring the displacement – KEYENCE LT-9001 Series User Manual

Page 33

Advertising
background image

2

Chapter

Basic

Operations

E LT-9001-IM

1

Press the [ENTER] button twice on the

measurement screen and place the cursor on

the value of [UP LIMIT].

2

Specify the value by using the [

t

], [

s

], [

]

and [

] buttons and press the [ENTER] button.

The value +100.00 is specified in this example.

3

Place the cursor on [LO LIMIT] by using the

[

] and [] buttons.

4

Place the cursor on the value by pressing the

[ENTER] button.

5

Specify the value by using the [

t

], [

s

], [

]

and [

] buttons and press the [ENTER] button.

The value –100.00 is specified in this example.

6

Press the [ESCAPE] button to return to the

measurement screen.

7

Set the current position as a reference point

by pressing the [ZERO] button.

The displacement based on this reference point

is displayed on the screen after this setting.

The value based on the current position as the

reference point is displayed on the measurement

screen. When the measurement target moves, the value

of the measured value display changes to the value of

the level difference between the former reference point

and the current reference point. Responding to the

change of value, the trend graph changes.

Reference

Measuring the Displacement

2-15

1

Press the [SCREEN] button on the

measurement screen to display the light

intensity screen.

2

Move the cursor by using the [

t

] or [

s

]

button to change the light intensity level.

Set the light intensity level to a higher level of

light intensity, but less than the peak.

3

Press the [SCREEN] button to return to the

measurement screen.

Setting the light intensity level is completed.

How to measure the displacement is described next.

Setting the Light Intensity Level

When the measurement target moves,
the measured value and the trend
graph changes according to the target.

LOW

HIGH

Advertising