Default values and setting range – KEYENCE LT-9001 Series User Manual
Page 43

2
Chapter
Basic
Operations
E LT-9001-IM
2-25
The default values and setting range of the LT-9001 parameters are listed below.
Default Values and Setting Range
Setting contents
Setting range
Default value
Notes
Lower limit Upper limit
Measurement range 1 of area1
– 550 or lower + 550 or higher
– 400
Area
Measurement range 2 of area1
– 550 or lower + 550 or higher
– 300
Measurement range 1 of area2
– 550 or lower + 550 or higher
+ 300
Measurement range 2 of area2
– 550 or lower + 550 or higher
+ 400
[(scan width/2)+scanning
Scan
Center position
– 550
+ 550
0
center position] is within
the range of ±550
Dark
Setting range of [HI]
1
255
100
LO<HI
Setting range of [LO]
0
254
20
Mask
Setting range of [HI]
– 400
+ 400
+ 100
Setting range of [LO]
– 400
+ 400
– 100
Light intensity level
0
255
30
Display
Upper limit
– 9999.99
+ 9999.99
+ 300.00
Lower limit<Upper limit
Lower limit
– 9999.99
+ 9999.99
– 300.00
Tolerance
Upper limit
– 9999.99
+ 9999.99
+ 200.00
Lower limit<Upper limit
Lower limit
– 9999.99
+ 9999.99
– 200.00
Offset
Offset
– 9999.99
+ 9999.99
0.00
Analog
Analog + 10V
– 9999.99
+ 9999.99
+ 200.00
– 20.00
Analog – 10V
– 9999.99
+ 9999.99
– 200.00
Measured value of the 1st point
– 9999.99
+ 9999.99
0.00
( < and < )
Calibration
Calibrated value of the 1st point
– 9999.99
+ 9999.99
0.00
and (0.5
Span value after the
Measured value of the 2nd point
– 9999.99
+ 9999.99
+ 100.00
calibration is done<4.0000)
Calibrated value of the 2nd point
– 9999.99
+ 9999.99
+ 100.00
Display
Upper limit
– 9999.99
+ 9999.99
+ 300.00
Lower limit<Upper limit
Lower limit
– 9999.99
+ 9999.99
– 300.00
Tolerance
Upper limit
– 9999.99
+ 9999.99
+ 200.00
Lower limit<Upper limit
Lower limit
– 9999.99
+ 9999.99
– 200.00
Offset
Offset
– 9999.99
+ 9999.99
0.00
Analog
Analog + 10V
– 9999.99
+ 9999.99
+ 200.00
– 20.00
Analog – 10V
– 9999.99
+ 9999.99
– 200.00
Measured value of the 1st point
– 9999.99
+ 9999.99
0.00
( < and < )
Calibration
Calibrated value of the 1st point
– 9999.99
+ 9999.99
0.00
and (0.5
Span value after
Measured value of the 2nd point
– 9999.99
+ 9999.99
+ 100.00
calibration<4.0000)
Calibrated value of the 2nd point
– 9999.99
+ 9999.99
+ 100.00
Tolerance
Upper limit
– 999999
+ 999999
+ 20000
Lower limit<Upper limit
Lower limit
– 999999
+ 999999
– 20000
Offset
Offset
– 999999
+ 999999
0
Analog
Analog + 10V
– 999999
+ 999999
+ 20000
– 20.00
Analog – 10V
– 999999
+ 999999
– 20000
Measured value of the 1st point
– 999999
+ 999999
0
( < and < )
Calibration
Calibrated value of the 1st point
– 999999
+ 999999
0
and (0.5
Span value after
Measured value of the 2nd point
– 999999
+ 999999
+ 10000
calibration<4.0000)
Calibrated value of the 2nd point
– 999999
+ 999999
+ 10000
C
o
m
m
o
n
Units
specified
in
the
measurement
selection
and
in
the
area
setting
Slant,
Δ
Slant
Area
The setting ranges differ according
to the manufacturing variations of
individual measuring units.
Displacement,
Transparent
thickness,
Profile
1
1
2
3
4
1
2
3
4
1
2
3
4
2
1
2
1
2
1
2
1
3
2
4
1
2
4
3
1
1
2
4
3
1
2
2
|
|
|
|
|
|
[µm]
[°]
[µm
2
]