Default Values and Settings Range (LT-9030 (M))

The default values and the setting range of the setting contents of the displacement mode are shown below.

Displacement Mode

Chapter 3 “Light Intensity Screen” – “Setting the
Light Intensity Level (page 3-8)

Chapter 3 “Measurement Screen” – “Setting the
upper and lower limits of the trend graph display”
(page 3-6)

Chapter 5 "OUT Settings" - "LIMITS" (page 5-7)

Chapter 3 "OUT Settings" - "MEASUREMENT" (page 3-10)

Chapter 3 "OUT Settings" - "SELECT SURFACE"
(page 3-12)

Chapter 5 "OUT Settings" - "AVERAGE " (page 5-8)

Chapter 5 "OUT Settings" - "HOLD MODE"
(page 5-9)

Chapter 5 "OUT Settings" - "OFFSET" (page 5-14)

Chapter 5 "OUT Settings" - "ANALOG output"
(page 5-15)

Chapter 5 "OUT Settings" - "CALIB" (page 5-16)

Chapter 3 "BASIC Settings" - "Scan Width"
(page 3-15)

Chapter 3 "BASIC Settings" - "DARK" (page 3-17)

Chapter 3 "BASIC Settings" - "DARK" (page 3-17)

Chapter 3 "BASIC Settings" - "DARK" (page 3-17)

Chapter 3 "BASIC Settings" - "MASK" (page 3-18)

Chapter 3 "BASIC Settings" - "MASK" (page 3-18)

Chapter 5 "OPTIONAL Settings" - "CAMERA IMAGE" (page 5-18)

Chapter 5 "OPTIONAL Settings" - "FOCUS" (page 5-18)

Chapter 5 "OPTIONAL Settings" - "SCROLL" (page 5-18)

Chapter 5 "OPTIONAL Settings" - "GRAPH DISPLAY" (page 5-18)

Chapter 5 "OPTIONAL Settings" - "DIGITS"
(page 5-18)

Chapter 5 "OPTIONAL Settings" - "I/O" (page 5-20)

Chapter 5 "OPTIONAL Settings" - "GAIN" (page 5-20)

Setting contents

Reference pages

Setting range

Default

value

30

+100.00

–100.00

+100.00

–100.00

+600.00

–600.00

+200.00

–200.00

+100.00

+100.00

+400

–400

Displacement

Maximum

[MAX]

Maximum

[MAX]

2

0.00

0.00

0.00

120/4

100

20

OFF

OFF

ON

ON

OFF

Normal

[NORMAL]

Binary

[BINARY]

Standard

Center fix

Medium

Displacement mode

Program

Run

Programs

GRAPH DISPLAY

OUT settings
(OUT1/OUT2)

Basic

settings

Optional

settings

Tolerance

Output

Calibration

Scan

Dark

Mask

Display

I/O

GAIN

1st point/measured value

1st point/calibrated value

2nd point/measured value

2nd point/calibrated value

Analog +10V

Analog –10V

Measurement mode

Offset

Scan Width

Darkout

Darkout range (HI)

Darkout range (LO)

Mask

Mask range (HI)

Mask range (LO)

Camera Image

Focus

Graph display

Scroll

DIGITS

GAIN

I/O

Light intensity level

OUT1 Upper limit

OUT1 Lower limit

OUT2 Upper limit

OUT2 Lower limit

Upper limit

Lower limit

Select

mesurement

Measurement surface

(One surface)

Measurement surface

(Two surfaces)

Number of measurement

times for averaging

OFF, ON

OFF, 120/2, 120/4,
120/8, 240/2, 240/4,
240/8, 400/2, 400/4,
400/8, 560/2, 560/4,
560/8, 4/1

OFF, ON

ON, OFF

ON, OFF

0~255

–9999.99 ~ +9999.99*

–9999.99 ~ +9999.99*

–9999.99 ~ +9999.99*

–9999.99 ~ +9999.99*

–9999.99 ~ +9999.99*

–1500 ~ +1500

1 ~ 255

0 ~ 254

OFF, 1-Digit, 2-Digit

Binary, Judgment output

Low, Medium, High

Displacement, Transparent object thickness

MAX, M1, M2, +1P, +2P, +3P
+4P, –1P, –2P, –3P, –4P

2 ~ 128 (256 ~ 4096)

Center fix, Maximum displacement,
Minimum displacement,
Average displacement

Normal [NORMAL], Auto peak hold [A.PEAK H],
Auto bottom hold [A BOTM H], Auto P-P hold
[A P-P H], Average hold [AVER. H],Peak hold
[PEAK HLD], Bottom hold [BOTTOM H], P-P
hold [P-P HOLD], Sample hold [SAMPLE H]

Normal, High sensitivity

Chapter 5 "OPTIONAL Settings" - "DISPLAY UNIT"
(page 5-19)

Display unit

μm

μm,mil

*The values differ according to the setting of the digit and the area.