Check parameter command format – KEYENCE LT-9001 Series User Manual

Page 145

Advertising
background image

8

Chapter

RS-232C

8-15

This section describes command format to check the setting contents.

Command list

If the LT-9001 Series receives the response command of the change parameter command as an incoming

command, the parameter will be sent back.

Refer to “Outline of Command Format” (page 8-3) for commands.

* Commands with an asterisk (*) can be used only for the LT-9010 (M).

Check Parameter Command Format

E LT-9001-IM

Incoming command

Response command

Limits

S R

,

F

I

CR

S R

,

F

I

,

o

CR

FINE mode*

S R

,

A V CR

S R

,

A V

,

w CR

Number of times for
averaging*

S R

,

M K CR

S R

,

M K

,

o

CR

Mask

S R

,

D O CR

S R

,

D O

,

o

CR

Dark-out

S R

,

D R CR

S R

,

D R

,

,

r

r

r

r

r

r

CR

Dark-out range

S R

,

A R CR

S R

,

A R

,

s

s

CR

,

Area*

S R

,

S M CR

S R

,

S M

,

w CR

Number of data for smoothing*

S R

,

M S

,

x

CR

S R

,

M S

,

x

,

g

CR

HOLD mode

S R

,

O A

,

x

CR

S R

,

O A

,

x

,

i

CR

Number of times
for averaging

S R

,

S C

,

m CR

S R

,

S C CR

Scan width/interval

Display

Symbol

Program No. check

P R CR

,

d

CR

P R

Analog scaling

S R

,

A S

,

x

CR

S R

,

A S

,

x

,

h

h

h

h

h

h

h

,

h

h

h

h

h

h

h

CR

h

h

Upper/lower limit

S R

,

L M

,

x

CR

S R

,

L M

,

x

,

h

h

h

h

h

h

h

,

h

h

h

h

h

h

h

CR

h

h

Calibration

S R

,

C L

,

x

CR

S R

,

C L

,

x

h

h

h

h

h

h

h

,

,

,

h

h

h

h

h

h

h

,

h

h

h

h

h

h

h

h

h

h

h

h

h

h

CR

h

h

h

h

Mask range

S R

,

M R CR

S R

,

M R

,

,

h

h

h

h

h

h

h

h

h

h

h

h

h

h

CR

h

h

Graph display upper/
lower limit

S

R

,

A A CR

S R

,

A A

,

o CR

Auto slant correction*

S

D

,

S E CR

S D

,

S E

,

o CR

GAIN

S

R

,

,

G L

x

CR

CR

h

h

h

h

h

h

h

h

h

h

h

h

h

h

,

,

S R

,

G L

,

x

h

h

Offset

S R

,

O F

,

x

CR

S R

,

O F

,

x

,

h

h

h

h

h

h

h

CR

h

d : Program number

e : Measurement target

f : Select measurement

g : Measurement mode

hhhhhhhh : Parameter

i : Number of times for averaging n : Run mode

lllll : Scanning position

m : Scan width/interval

o : Operation type

rrr : Light intensity

s : Area setting

t : Area number

w : Smoothing number of times x : OUT number

Scan center position*

S R

,

S

L CR

S R

,

S L

,

l

l

l

l

CR

l

Area range*

S R

,

A W

,

t

CR

CR

S R

,

A W

,

t

,

,

l

l

l

l

l

l

l

l

l

l

P

rogram

Light

intensity

O
U

T

Basic

Optional

Light intensity
level

CR

S R

,

L

T

R

,

,

L T

r

r

r

CR

S

Select surface

S R

,

S U

,

x

CR

S R

S U

,

x

,

e

,

e

CR

,

Run mode/
measurement

S R

,

M D CR

R

,

M D

,

n

,

f

,

f

CR

S

The “ ” portion indicates a parameter or a measured value.