KEYENCE BL-700 Series User Manual

Page 104

Advertising
background image

Chapter 5 Serial Communication

90

5

● Online test ON

Command: #TEST1
Response: OK

● Online test OFF

Command: #QUIT
Response: OK

● Online test check

Command: #TEST
Response: #TESTn

n = 0: Online test OFF
1: Online test ON

Command: BCLR
Response: OK

Command: SSET
Response: OK

● Laser off

Command: LOCK
Response: OK

● Resetting Laser off

Command: UNLOCK
Response: OK

•

When the Laser off command is executed, bar code read operation (laser
emission) is disabled until the Laser off command is reset by using UNLOCK
command.

•

The Laser off command is retained even after the power is turned off.

Command: RESET
Response: OK

Online test mode

Sets to online test mode (

➮ see P. 60).

Clearing transmission buffer

Clears data stored in the transmission buffer.

Shift to setting mode

Enters the setting mode (

➮ see P.4).

Laser off/Resetting Laser off

Turns off the laser emission when the laser beam may cause injury to an operator
(

➮ see P.2).

Reset

Resets the BL-700 software.