Appendix F Sample Program for the PLC Link

The sample program stores the read data in D105 (DM105) and subsequent DMs.
You can change the program to suit your application.
Before using the sample program, check that your system meets the following
requirements.

BL-700 settings

The scan method is “level signal trigger”.

Use the “PLC trigger area”.

The DM head address is “0000”.

Processing of data memory flag ... Sequential processing
*

This sample program uses the level signal trigger. However, it does not use the
+05 trigger input response area to check if the BL-700 successfully recognized
the +04 reading trigger area.

Data stored in D105 and
subsequent areas is processed.

2008

#0100

DW

DM0100

END

ENDH

0000

#0001

DW

DM0004

0000

#0000

DW

DM0004

#0002

DW

DM0100

2002

2010

DM0100

LDA

#0003

CMP

#0102

DW

DM0100

Program for the KV Series

Specify the head address of the
data memory area.

(Enter “2” in the data memory
flag. Use sequential processing to
process the flag.)

Enter “0000” for the reading
trigger input.

When DM0100 becomes “3”, the
specified processing is per-
formed.
After processing is completed,
enter “2” in DM0100.