Chapter 2 Connection and Installation

2

17

2.3.3 Terminals of I/O terminal block and connections

Connecting trigger input
The trigger input allows the BL-700 to start reading bar codes (turn on the laser
beam).
To turn ON the trigger input, supply 15 to 26 VDC between the trigger input termi-
nals.

Connecting OK/NG output
The OK/NG output indicates the result of the comparison with preset data, or
indicates whether reading is successful or not.

+

OK

NG COM

Load

Load

Internal circuit

+

Load

* Viewed from the left of the unit

Symbol

Description

Signal direction

TIM

Trigger input

Input

COM

Common terminal for trigger input

Input

OK

OK output

Output

NG

NG output

Output

COM

Common terminal for output

Output

TIM COM OK OG COM

15 to 26 VDC

+

+

TIM COM OK

TIM

COM

Internal circuit

+

+

* Rated load: 30 V max. (100 mA)