Chapter 3 Functions for Reading Operation

43

3

Unit operation status display
STABILITY LEDs indicate the following information in addition to reading stability.

Operation status

STABILITY LED display

Action to be taken

Power-on

LEDs turn on sequentially
from the bottom.

During setup

All the LEDs flash.

(

➮ see P.92)

Waiting for setting

The 1st, 3rd and 5th LEDs

In this status, send the settings from

data send/receive

from the top flash

the setup software. (Hold down the

(

➮ see P.73)

simultaneously.

TEST switch for 8 seconds to set the
data.)

Laser forced OFF

The bottom LED flashes.

When resetting laser forced OFF

(

➮ with LOCK

(with UNLOCK command), the unit

command,

returns to the initial operation at

see P.90)

power-on.

Unit error

Either of the 2nd, 3rd, or 4th

The unit may have failed or supply

LEDs from the top flashes.

voltage may have dropped. If supply
voltage is normal, the unit may have
failed. Contact the nearest
KEYENCE office or distributor.

PLC link error

The top LED flashes.

The error is reset by pressing the

(

➮ see P.117)

TEST switch again.

See P.116 for troubleshooting.